WATER TEMPERATURE
PROBLEM 1 - WATER TEMPERATURE WILL NOT CONTROL
TEMPERATURE TOO LOW OR NO HEAT
Remove 2” silver hole plug from brewer body.
Water temperature setpoint is controlled by lower left dial
on control board. Be sure pointer on dial is set to desired
temperature.
WATER TEMP
(ºF)
OFF
185
190
195
200
205
10
20
30
40 50
60
70
80
SOLENOID TIMER
(WATER VOLUME)
(SECONDS)
BREW SIGNAL TIMER:
- BREW LIGHT
END OF BREW BEEPER
(MINUTES)
2
3
4
5
6
7
8
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
page6of8
Remove top panel to check voltage at heating element terminals. When HEAT
indicator is lit, full line voltage must be present across heating element terminals.
voltage is present at element terminals and unit is not heating, replace heating
element p/n 8716-1. Also, be sure to replace gaskets p/n 8043-30.
voltage is NOT present, remove front panel. Be sure hi-limit thermostat is not
tripped. Press red button until it clicks and stays latched in the “set” position.
If hi-limit has tripped, find and rectify cause of over-temperature condition.
voltage is NOT present, examine wiring and connectors. Be sure multi-wire
cable between control and power board is in good condition and properly
connected to both boards. If wiring is OK, replace power board p/n 83636.
unit heats and controls, but HEAT indicator never lights, examine ribbon cable
connector at control board. If this is OK, membrane keypad p/n 83633 may
need to be replaced (non-critical item).
IF
IF
IF
IF
IF
IF
neither HEAT indicator glows nor power relay clicks as the dial is advanced
from minimum to maximum, replace control board p/n 83635.
temperature is consistently high or low, remove temperature probe from tank.
Clean calcium and lime build-up. If probe cannot be cleaned, replace probe
p/n 83644. Be sure to replace seal washer p/n 83731 at the same time.
Observe HEAT indicator, and listen for a “click” from power relay while turning
water temp. dial clockwise.
IMPORTANT
Energizing the brewer without water in the tank will usually cause the
hi-limit to trip, and can permanently damage the heating elements.
CAUTION
The following procedure exposes live electric circuits.
Use due care when working around electricity.
NOTE: Temperature cannot be adjusted during a brew cycle.
Turn dial fully counterclockwise to disable tank heater.
Service Bulletin 107.002