BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
DIAGNOSTICS - FLASHING LIGHTS AND BEEPING ALERTS
TEST FOR NORMAL OPERATION ON INITIAL START-UP
When power is first applied to the brewer, all LEDs will come on momentarily and alert
beeps four times.
The alert will beep once each time a key is pressed.
Press BREW BREW BREW CANCEL to initiate tank fill. BREW and HEAT LEDs flash
continuously. Press ON OFF to terminate fill.
Press ON OFF to energize brewer. Alert beeps five times and POWER and HEAT LEDs
on steady. HEAT LED goes off when water reaches setpoint temperature.
Pressing BREW key during a brew or before HEAT light goes out will cause BREW LED
to flash. A second brew will not be initiated.
Press CANCEL at any time during a brew to de-energize the water inlet valve.
NO lights and NO sound:
Be sure brewer is plugged into an appropriate receptacle and circuit breaker for that
circuit is turned on.
Check/reset hi-limit thermostat.
Check multi-wire cable from control board to power board. Cable must be properly
connected to both boards.
Check for line voltage at power board terminals LINE IN and NEUTRAL IN.
voltage is present and no lights/sound, replace power board p/n 83636.
NO lights, alert beeps on startup but no beep on keystroke:
Check ribbon cable from keypad to control board. Cable must be properly connected.
cable is properly connected, test keypad by connecting a new keypad to control
board. Replace keypad p/n 83633 if found defective.
IF
IF
CAUTION
The following procedure exposes live electric circuits.
Use due care when working around electricity.
Service Bulletin 107.002