PROBLEM 1 - BREW VOLUME (SHORT POT)TOO LITTLE
page4of8
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
BREW TIME & VOLUME
IF
IF
IF
WATER TEMP
F)
OFF
185
190
195
200
205
10
20
30
40 50
60
70
80
SOLENOID TIMER
(WATER VOLUME)
(SECONDS)
BREW SIGNAL TIMER:
- BREW LIGHT
END OF BREW BEEPER
(MINUTES)
2
3
4
5
6
7
8
Remove 2” silver hole plug from brewer body.
Water solenoid open time is controlled by upper dial
on control board. Be sure pointer on dial is set to desired
time in seconds.
Brewer must be installed on a water line with average
pressure of at least 20 PSI. Be sure water supply is connected
to brewer, and that water supply valve is fully open. Be sure any in-line filters are
clean and functioning properly.
Shut off water supply to unit. Remove solenoid cap
and clean filter screen. Be sure to reinstall screen
properly. Reinstall cap and turn on water supply.
FILTER
SCREEN
WASHER
INLET
FITTING
CAP
Using a reliable stopwatch, measure actual brew time against time on dial.
Set dripout time (lower right dial on controller) to minimum. Press BREW key.
BREW indicator will glow and relay on power board will click. At end of brew
cycle, three beeps sound and BREW indicator goes out.
brew time is acceptable, check water path for obstructions. Silicone hose from
inlet valve may be removed from tank fitting and directed to an empty decanter
to verify volume. NOTE: once tank is filled, any volume of water entering tank
will displace a like volume of water through the brew head.
Examine jumper at bottom of control board.
If jumper is across both pins, remove jumper
and reinstall on right pin only. This sets timing
range to 120 - 250 seconds.
brew time cannot be adjusted, or timing is outside of
useable range, replace control board p/n 83635.
volume remains too low even though brew timer may be adjusted and no
blockages can be found, replace water inlet solenoid p/n 85752.
1
VOLUME
CONTROL
JUMPER
NOTE: Time cannot be adjusted during a brew cycle.
Service Bulletin 107.002
6 of 10