Bloomfield WFAE-55FS Uživatelský manuál Strana 25

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 36
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 24
363 30007 OpManual for WFAE-55F/FS Electric Fryer
23
CLEANING INSTRUCTIONS (continued)
PREPARATION Drain oil from fryer before cleaning
FREQUENCY Monthly, or as needed
TOOLS Low-foaming commercial fryer cleanser
Metal disposal container
Press POWER SWITCH OFF.
Close DRAIN VALVE (lever horizontal). Fill FRYPOT with 4 gallons of
cold water.
Press POWER SWITCH to FRYER.
When water comes to a full boil, press POWER SWITCH OFF.
When boiling ceases, slowly add and stir in the LOW FOAMING
COMMERCIAL FRYER CLEANSER. Using the HIGH
TEMPERATURE BRUSH supplied with the fryer, stir until the
cleanser is completely dissolved.
Press POWER SWITCH to FRYER. When the water begins to boil,
press POWER SWITCH OFF. When the boiling subsides, again
press POWER SWITCH to FRYER. Repeat this procedure
continuously for five (5) minutes.
Press POWER SWITCH OFF. Allow the solution to set for thirty (30)
minutes.
Allow solution to cool to 120ºF (49ºC) or less before draining.
Place a suitable METAL container under the DRAIN VALVE. Open
DRAIN VALVE (lever vertical) to drain the cleaning solution.
NOTE: Drain no more than 4” at a time into the container to prevent
splashing and spilling.
Dispose of used solution as required by local
ordinances.
Rinse frypot with clean water. Dry with a soft clean cloth.
IMPORTANT:
Use a LOW-FOAMING
COMMERCIAL fryer cleanser
only.
IMPORTANT:
DO NOT press FRYER-OFF-
FILTER SWITCH to FILTER
with anything other than
shortening in the filter
reservoir. Water and/or
cleaning chemicals can:
cause severe oil splatter
damage the filter pump
contaminate cooking oil
and food product.
WARNING:
BURN HAZARD
TURN THERMOSTAT TO LOWEST TEMPERATURE SETTING
(FULLY COUNTERCLOCKWISE)
USE ONLY LOW-FOAMING COMMERCIAL FRYER CLEANSER.
CAREFULLY FOLLOW CLEANSER INSTRUCTIONS AND WARNINGS.
DO NOT LEAVE FRYER UNATTENDED
WHILE BOILING OUT FRYPOT.
WHEN WATER BEGINS FOAMING,
BE PREPARED TO TURN POWER SWITCH OFF.
Boiling water and splatter can result in moderate to serious injury.
WARNING
WFAE-55F (Manual Controls) HOT BOIL-OUT PROCEDURE
Zobrazit stránku 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 35 36

Komentáře k této Příručce

Žádné komentáře

Rivera-primo Do samochodu podręczniki użytkownika

Zaczynanie od H

Kliknij na poniższy alfabet, aby przejść do pełnej listy modeli zaczynających się od tej litery

Modele Rodzaj dokumentu
Headlamp Adapter Harness for 1116-0200 LED HEDLED
Instrukcja Użytkownika   Rivera Primo Headlamp Adapter Harness for 1116-0200 LED HEDLED User Manual, 1 strony