SERVICING INSTRUCTIONS (continued)
15
CAUTION:
SHOCK HAZARD
Live electrical circuits are
exposed during this procedure.
Use care to avoid uninsulated
electrical connectors.
Adjustments to be performed by
qualified technician only.
NOTE:
1/8 turn = approx 10ºF (5.5ºC)
TEMPERATURE ADJUSTMENT
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
FREQUENCY: As required to adjust delivered volume
TOOLS: Phillips head screwdriver
Satellite or other container to calibrate volume
1. Press HEATER ON/OFF switch to OFF. Turn POWER
switch on back of brewer OFF.
2. Remove TOP PANEL. Operating controls are accessible
through the top panel only.
3. Remove one of the plugs in the tank cover and insert a
thermometer of known accuracy.
4. Locate the CONTROL THERMOSTAT on the right side of the
top housing:
Turn CLOCKWISE to increase temperature
Turn COUNTER-CLOCKWISE to decrease temperature
1/8 turn is equal to approximately 10ºF change.
5. Turn POWER switch ON. Press HEATER ON/OFF switch to
ON.
6. Allow the brewer to come up to brewing temperature. When
READY-TO -BREW light comes on, check temperature on
thermometer. Readjust thermostat as necessary.
7. When desired temperature is achieved, remove thermometer,
replace tank plug and reinstall top panel.
Procedure is complete
Zobrazit stránku 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 25 26

Komentáře k této Příručce

Žádné komentáře

Rivera-primo Do samochodu podręczniki użytkownika

Zaczynanie od H

Kliknij na poniższy alfabet, aby przejść do pełnej listy modeli zaczynających się od tej litery

Modele Rodzaj dokumentu
Headlamp Adapter Harness for 1116-0200 LED HEDLED
Instrukcja Użytkownika   Rivera Primo Headlamp Adapter Harness for 1116-0200 LED HEDLED User Manual, 1 strony